DETECTORS
Photoelectric Smoke Detector
Series 65A
Orient Series 65A consolidates well-demonstrated detecting innovations, together with advances in materials and device innovation, including an IC in light of that is utilized as a part of XP95 simple addressable locators. Having a wide working voltage of 9-33V, the Orient Series 65A territory comprises ionization, incorporating ionization and photoelectric smoke detectors, 2 evaluations of a warm finder, and a standard base. Each sort of locator has an LED that flashes constantly in remain-by mode.
Photo-electric smoke indicators solidify a beating LED arranged in a chamber inside the cabin of the identifiers. The chamber is expected to restrict light from any external source. As an indication, the LED is a photodiode that consistently does not select the area of light created by the LED. If there should be an occurrence of smoke from a fire entering the chamber, the light pulse from the LED will be scattered and subsequently enlisted by the photodiode. If the photodiode “sees” smoke on the two following pulses, the indicators change into caution.
state and the marker LED enlightens. The identifier lodging is unclear to that of the ionization indicators yet has a pointer LED which is clear in remain by state, in any case, conveys red light in caution.
Features
Thermal Detector
A Thermal Detector easily absorbs radiation and changes temperature. It is operated by using a matched pair of thermistors to sense heat. One thermistor is exposed to sense temperature and the other is sealed. When this occurs, a potential difference is formed between the other ends of metals. Since potential differences are temperature-dependent, temperature values or changes in temperature result in an imbalance that can be determined by calibration.
Thermal Detectors Series 65A externally, the thermal detectors are distinguishable from the smoke detectors by having wide openings to the surrounding atmosphere to allow good movement of air around the external thermistor.
Features
Specifications
Operating Voltage | DC (9/33) V |
Start-Up Current | 170 μA |
Standby Current | 50 μA |
Alarm Current | 40 mA/90 mA |
Reset Voltage | ≤1V |
Reset Time | ≤ 3s |
Alarm Response Threshold | 59 °c static temperature, and 11.1°c /min rate-of-rise temperature |
Operating Temperature | -10 °C ~ +37.8 °C |
Operating Humidity | 59 °c static temperature and 11.1°c /min rate-of-rise temperature |
Alarm Indicator | Two continuous emitting red LEDs |
Dimensions (Excluding Contacts) | 0100 mm” 37 mm |
Ingress Protection Rating | IP-43 |
CONTROL PANEL
Orient KRCP3
Extinguishant Control Panel
Designed and manufactured to the highest standards in a quality-controlled environment, Orient KRCP3 offers outstanding value and performance for all small to medium fixed firefighting installations. With three initiation circuits as standard, release can be configured to activate from any combination of detection zone inputs to allow (among other combinations) any two from three type activations such as would be required for detection in ceiling void, room, and floor void applications.
The extensive configuration options of the Orient KRCP3 allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety. The countdown timer is duplicated on up to seven remote status units to provide local indication of the system status. With all of the electronics mounted on a single, easily removable, steel plate panels are both robust and easy to install.
Features
ALARMS
Fire Alarm Bell
with Weatherproof Back Box
Features
Installation
Specifications
Part Number | OCI-B6-24 | OCI-B10-24 |
Model | OR-24 | OR-10-24 |
Gong Size | 6” | 10” |
Voltage | 24VDC | 24VDC |
Current | 20mA | 100mA |
Sound Level | 96dB at 1 m | 96dB at 1 m |
Driving Way | Motor | Coil |
Weight | 1 kg | 1.5 kg |
Operating Temperature | 32°F to 120°F | 32°F to 120°F |
(Indoor Application) | (0°C to 48°C) | (0°C to 48°C) |
Operating Temperature | -32°F to 150°F | -32°F to 150°F |
(Outdoor Application) | (-35°C to 65°C) | (-35°C to 65°C) |
Color/ Material | Red/Metal | Red/Metal |
BB-WP Dimension | 4.25”W x 4.25”H x 1.5”D | 4.25”W x 4.25”H x 1.5”D |
Outdoor Evacuation Signal
Horn/Strobe
The Outdoor Evacuation Signal is an outdoor horn and strobe combination that offers both visible and audible alarms for fire emergency needs. It offers a fixed 75-candela strobe and has a continuous or synchable temporal 3 in 2400Hz, mechanical and chime as well as a whoop tone. All tones are easy to change in the field by the use of switches.
Features
Unit Dimensions
Outdoor Temperature
Outdoor Enclosure
Unit Dimensions
Strobe Light Box
Evacuate & Gas Discharged
The Evacuate Strobe Light Box is used as the first alarm (1st) warning before the discharge of the fire suppression system. The signage casing is made of an electro-galvanized steel sheet and is epoxy powder coated (Black) to last. It has a dimension of size 265mm(L) x 105mm(W) x 110mm(H).
The Gas Discharged Strobe Light Box is used as the second alarm (2nd) and discharge warning of a fire suppression system that has been discharged. The signage casing is made of electro electro-galvanized steel sheet and is epoxy powder coated (Black) to last. It has a dimension of size 265mm(L) x 105mm(W) x 110mm(H).